日本亲与子乱人妻hd-少妇洁白无删减版178txt-а天堂中文在线官网-乌克兰少妇video

Hello, welcome to Xuzhou Tenglong Steel Structure Technology Co., Ltd. official website!

Your Current Location:Home > News > TECHNICAL KNOWLEDGE

Technical measures for steel structure
release time:2019/4/25 23:37:20      hit count:2011

When the steel structure is damaged, we need to find and solve the problem immediately. The main factors of steel structure damage are:

1) the structure's bearing capacity is insufficient due to load changes, overdue service, and changes in codes and regulations;

2) due to all kinds of accidental deformation, distortion, disability and sag of the component, the section of the component is weakened, the rod is warped and the connection is cracked;

3) deformation, cracking and warping of components or joints caused by temperature difference;

4) the section of steel structure members is weakened due to corrosion of chemical substances and electrochemical corrosion;

5) others include design, production, construction errors and illegal use and operation during the service period.

There are three main technical measures for steel structure reinforcement:

1) cross-section reinforcement method: steel is used to reinforce parts or the whole length of the component, and the whole part is made to bear common stress;

2) change the calculation diagram: add additional support, adjust the load distribution, reduce the level of internal force, force displacement on the statically indeterminate structure support, reduce the peak stress;

3) prestressed cable method: use high strength cable to strengthen the weak link of the structure or improve the overall bearing capacity, stiffness and stability of the structure.


News you are interested in
Previous:What are the differences between steel structures
Next:No more

Back to list

主站蜘蛛池模板: 洪江市| 敦煌市| 宜兴市| 水富县| 莎车县| 崇州市| 泰兴市| 巴楚县| 康保县| 洛浦县| 威海市| 米脂县| 左权县| 休宁县| 黄冈市| 稻城县| 西藏| 云霄县| 丹江口市| 迭部县| 常山县| 泗水县| 平度市| 灵宝市| 宝丰县| 老河口市| 确山县| 霍山县| 六安市| 绥化市| 甘肃省| 龙口市| 成武县| 泽普县| 虹口区| 卢氏县| 洛隆县| 双牌县| 金昌市| 饶平县| 梅州市|